Primer Design

Primers can be designed directly against the sequences annotated in CnidoSite, or against a sequence you paste in. Design is performed by primer3 (version 2.6.1) running on this server — your sequence is not sent to any third-party website. For reference, the primers released with this database were designed with an optimal melting temperature of 60°C (58–62 °C), an optimal primer length of 20 bp (18–24 bp), and a GC content between 40% and 60%, with self-complementarity restricted to limit primer-dimer formation; that parameter set is the CnidoSite published protocol preset below.

Template taken from CnidoSite: FUN_038238-T1 (FUN_038238-T1), 2,272 bp.
Template

Two ways to supply a template: pick a species and a gene / transcript ID, or paste your own sequence. If the gene ID is found it is used; the pasted sequence is used otherwise. A template must be at least 30 bp.

Load example sequence
Primer parameters
Advanced parameters (any field left empty keeps the preset value)

A value that is not a number is ignored. The product size range is applied only when both of its fields are filled in and the maximum is at least the minimum.

Melting temperature
Primer length and GC content
Product and output
Self-complementarity and probe
Download TSV
Design results sorted by primer3 penalty, lowest first

Template 2,272 bp · parameter preset CnidoSite published protocol (Tm 60 [58-62] °C, 20 [18-24] bp, GC 40-60%) · 5 primer pairs returned.

Pair Left primer (5'→3') Position Len Tm (°C) GC (%) Right primer (5'→3') Position Len Tm (°C) GC (%) Product (bp) Penalty
1 GCGTTGTAAATGGCATCGCT 1155–1174 20 59.901 50.000 CTGGGGTCAGTAGCCAGTTG 1429–1448 20 60.036 60.000 294 0.135
2 TAGTGCCCCGAGACCCAATA 1734–1753 20 60.032 55.000 ACGTAGGCTGGTGTTTCGTT 1991–2010 20 59.895 50.000 277 0.137
3 GTGAATCCTGCGTCATCCCA 1463–1482 20 60.108 55.000 TATTGGGTCTCGGGGCACTA 1734–1753 20 60.032 55.000 291 0.140
4 GTGAATCCTGCGTCATCCCA 1463–1482 20 60.108 55.000 GGTCTAAGTTGGTGGGAGCC 1682–1701 20 60.035 60.000 239 0.143
5 ACCCACCAGAGAGTGCTAGT 1302–1321 20 59.885 55.000 CTGGGGTCAGTAGCCAGTTG 1429–1448 20 60.036 60.000 147 0.151
Primer map pair 1 (lowest penalty) · product 294 bp at template position 1,155–1,448 · the template track shows a 1,500 bp window of the 2,272 bp template — the blue segment on the top bar is where that window sits, and every scale is in template coordinates · the two tracks are drawn at different scales

Left primer — binds the template strand as listed (5′→3′)Right primer — its reverse complement binds hereProductWindow drawn in the template track

whole templatethe 1,500 bp drawn in the track below · template 552–2,051 of 2,272Template1,500 bp windowproduct 294 bp · template 1,155–1,448product 294 bpleft primer, template 1,155–1,174right primer anneals here, template 1,429–1,4485529271,3021,6762,051Amplicon294 bpleft primer GCGTTGTAAATGGCATCGCT · 5′→3′right primer CTGGGGTCAGTAGCCAGTTG · its reverse complement binds the template strandinterior 254 bp1,1551,2281,3021,3751,448
Left primer
GCGTTGTAAATGGCATCGCT
template 1,155–1,174 · 20 bp · Tm 59.901 °C · GC 50.000 %
Right primer
CTGGGGTCAGTAGCCAGTTG
template 1,429–1,448 · 20 bp · Tm 60.036 °C · GC 60.000 %

Amplicon sequence (5′→3′ on the template strand, 294 bp) — blue is the left primer, red is where the right primer anneals. Copy from here to order or to check a base by eye.

GCGTTGTAAATGGCATCGCTTCGCTCTTTTTGACCTCTTTGATCATTGGTATTTTTGTAGTTGTTATCCTGTCCTTGGTCCTTCCCATTTATCGTAGATCTGATTCGCCAATTGAACTTTCTTACCAGCCCATTTCAGACGATGATAACCCACCAGAGAGTGCTAGTCTAATTCCCAGTCCCCCTATGCCTACCACGTACAACTCAATAAATCGCCAAGCATCAGATGAATCCCATTCCTTTGAGGAGTCTGGGGTACCTTTATTAACTCCAAACAACTGGCTACTGACCCCAG

The right primer is listed as its own 5'→3' sequence; what anneals to the template strand shown here is its reverse complement, so the highlighted stretch is complementary to the listed sequence. That is expected.

How to read this table. Position is a 1-based interval on the template, and both primers use the same convention: it is the stretch the primer occupies on the template strand (for the left primer, starting at its 5’ end; for the right primer, the region it anneals to, i.e. where the reverse complement of the listed sequence sits on the template). The two coordinates in a row can therefore be subtracted directly, and the amplicon view above marks both of them so you can check them by eye. Penalty is primer3’s weighted sum of the deviations from your constraints — lower is better, and the pairs are returned in that order. Tm is computed by primer3 from the SantaLucia thermodynamic parameters at the salt and primer concentrations in effect. The primer sequences themselves are 5’→3′ and can be ordered as they stand; the right primer anneals to the template as its reverse complement.

Specificity has not been assessed. This page only designs primers; it does not check whether they also anneal elsewhere in the genome or transcriptome. Once you have candidates, confirm each primer sequence with this site’s BLAST. The Tm and GC settings above are the design targets, and the annealing temperature still has to be optimised at the bench.

TOP