Primer Design

Primers can be designed directly against the sequences annotated in CnidoSite, or against a sequence you paste in. Design is performed by primer3 (version 2.6.1) running on this server — your sequence is not sent to any third-party website. For reference, the primers released with this database were designed with an optimal melting temperature of 60°C (58–62 °C), an optimal primer length of 20 bp (18–24 bp), and a GC content between 40% and 60%, with self-complementarity restricted to limit primer-dimer formation; that parameter set is the CnidoSite published protocol preset below.

Template taken from CnidoSite: amic_s0007.g65.t2 (amic_s0007.g65.t2), 13,128 bp.
Template

Two ways to supply a template: pick a species and a gene / transcript ID, or paste your own sequence. If the gene ID is found it is used; the pasted sequence is used otherwise. A template must be at least 30 bp.

Load example sequence
Primer parameters
Advanced parameters (any field left empty keeps the preset value)

A value that is not a number is ignored. The product size range is applied only when both of its fields are filled in and the maximum is at least the minimum.

Melting temperature
Primer length and GC content
Product and output
Self-complementarity and probe
Download TSV
Design results sorted by primer3 penalty, lowest first

Template 13,128 bp · parameter preset CnidoSite published protocol (Tm 60 [58-62] °C, 20 [18-24] bp, GC 40-60%) · 5 primer pairs returned.

Pair Left primer (5'→3') Position Len Tm (°C) GC (%) Right primer (5'→3') Position Len Tm (°C) GC (%) Product (bp) Penalty
1 CGCGACGTGTTGTTCTTGTT 12860–12879 20 59.974 50.000 ATGGACGACTTGCTGTTCGT 12940–12959 20 59.966 50.000 100 0.059
2 GTTTGTGGACAGACAACCGC 6915–6934 20 59.971 55.000 GCTGAGTTGCGGCTTTCAAA 7127–7146 20 59.969 50.000 232 0.060
3 TGTGCGAGAAAAGCTGTTGC 2295–2314 20 59.971 50.000 CTGCAAACCCTGTGAGCAAC 2435–2454 20 59.969 55.000 160 0.060
4 CCACTCGACTTCCTTTGCCT 9541–9560 20 59.965 55.000 CATCTTGTTTCGCGCCTAGC 9701–9720 20 59.973 55.000 180 0.062
5 GCTAGGCGCGAAACAAGATG 9701–9720 20 59.973 55.000 ATGACTGAGAACTGCCAGGC 9886–9905 20 60.036 55.000 205 0.062
Primer map pair 1 (lowest penalty) · product 100 bp at template position 12,860–12,959 · the template track shows a 1,500 bp window of the 13,128 bp template — the blue segment on the top bar is where that window sits, and every scale is in template coordinates · the two tracks are drawn at different scales

Left primer — binds the template strand as listed (5′→3′)Right primer — its reverse complement binds hereProductWindow drawn in the template track

whole templatethe 1,500 bp drawn in the track below · template 11,629–13,128 of 13,128Template1,500 bp windowproduct 100 bp · template 12,860–12,959left primer, template 12,860–12,879right primer anneals here, template 12,940–12,95911,62912,00412,37912,75313,128Amplicon100 bpleft primer CGCGACGTGTTGTTCTTGTT · 5′→3′right primer ATGGACGACTTGCTGTTCGT · its reverse complement binds the template strandCGCGACGTGTTGTTCTTGTTATGGACGACTTGCTGTTCGTinterior 60 bp12,86012,88512,91012,93412,959
Left primer
CGCGACGTGTTGTTCTTGTT
template 12,860–12,879 · 20 bp · Tm 59.974 °C · GC 50.000 %
Right primer
ATGGACGACTTGCTGTTCGT
template 12,940–12,959 · 20 bp · Tm 59.966 °C · GC 50.000 %

Amplicon sequence (5′→3′ on the template strand, 100 bp) — blue is the left primer, red is where the right primer anneals. Copy from here to order or to check a base by eye.

CGCGACGTGTTGTTCTTGTTGTTAATGCTGTCCATGTCAGTCGACGTGTCGACACATTCCCGCGAAGCCAAGCAGAGATGACGAACAGCAAGTCGTCCAT

The right primer is listed as its own 5'→3' sequence; what anneals to the template strand shown here is its reverse complement, so the highlighted stretch is complementary to the listed sequence. That is expected.

How to read this table. Position is a 1-based interval on the template, and both primers use the same convention: it is the stretch the primer occupies on the template strand (for the left primer, starting at its 5’ end; for the right primer, the region it anneals to, i.e. where the reverse complement of the listed sequence sits on the template). The two coordinates in a row can therefore be subtracted directly, and the amplicon view above marks both of them so you can check them by eye. Penalty is primer3’s weighted sum of the deviations from your constraints — lower is better, and the pairs are returned in that order. Tm is computed by primer3 from the SantaLucia thermodynamic parameters at the salt and primer concentrations in effect. The primer sequences themselves are 5’→3′ and can be ordered as they stand; the right primer anneals to the template as its reverse complement.

Specificity has not been assessed. This page only designs primers; it does not check whether they also anneal elsewhere in the genome or transcriptome. Once you have candidates, confirm each primer sequence with this site’s BLAST. The Tm and GC settings above are the design targets, and the annealing temperature still has to be optimised at the bench.

TOP